Products

OPT-QE Quantum efficiency system
January 14, 2019
Optosense SC-700 Spin Coater System
October 27, 2021
Show all

LSS Automatic Solar IV Characterization System

Description
DOWNLOAD PDF CATALOG

Solar Simulator system automatically measures current-voltage (I-V) under various light intensities

For Example

Solar Simulator system automatically measures power-voltage (P-V) under various lightintensities

TECHNICAL DATA AND CALIBRATION RESULTS
PHOTOVOLTAIC I-V TEST RESULTS

LSS SOLAR SIMULATOR SPECTRAL SOLAR IRRADIANCE MATHING
SPECTRAL IRRADIANCE OF LSS SOLAR SIMULATOR FOR VARIOUS INTENSITIES

SPECTRAL SOLAR IRRADIANCE OF LSS SOLAR SIMULATOR

SOLAR SIMULATOR
I-V CHARACTERIZATION SYSTEM, SOURCEMETER
SAMPLE HOLDER
CONNECTIONS
SOFTWAREs

Solar IV characterization Software
Solar Life-Time Software
Transient photocurrent software
Photovoltaic mechanism analysis software
Solar Cell I-V Characterization System
This system analyze all photovoltaic and photoconducting characteristics of all solar cells such Dye sensitized solar cell, quantum dots solar cells, Organic solar Cells, Silicon Solar cells, Thin films solar Cells under various solar light intensities from 0.1 W/cm2 to 1500 W/m2.
This system is a complete current-voltage (I-V), current-time (I-t) and power-voltage (P-V) measurement environment.

The system contains the following elements:
– Maintenance Free Solar Simulator (FSS)
I-V system, source meter
Voltage range: -24 V to +24 V
Current range: 100 nA to 500 mA
– I-V Solar IV software
– Solar cell probes
– Solar cell probes
– Calibrated Reference solar cell
19 independently controlled LED wavelengths from 400 nm – 1100 nm

Front panel control of the 6 IEC wavelength bands
Rapid turn-on / turn-off
Factory calibrated AM1.5G spectral match
User storable spectrum
Factory calibrated intensity
User configurable intensity offset
Front panel LED Fault indication
USB Communications
Meets Class AAA specification for IEC 60904-9, JIS C 8912, and ASTM E 927-05
2” X 2” illumination area at 1 sun
Standoff distance of 8” (203 mm) nominal or variable
Height adjustment from -0.6” to 4.6” (-15 mm to 117 mm) from the working plane
PV Cell Placement Indicator
Easy-Adjust light adjustment
Can be mounted pointing up, down, or to the side with 90o rotational accessory Temperature controlled for stable output

FULL AUTOMATIC SOLAR SIMULATOR

Bands 400-500, 500-600, 600-700, 700-800, 900-1100 nm 6 BANDS
Light control USB
Automatically intensity light Control 0.1 to 1000 W/m2 (0.1 to 1.0 sun or more) by a certain step
Power Requirements 100-240 VAC, 50-60 Hz, 300W
Operating Temp Range 20oC to 30oC
Humidity <85%, relative, non-condensing
Certificate ISO 9001 :2015
Illumination Area 2”X2” (51mmX51mm)
Total Power Output (1.5 sun)
Uniformity Classification1
Temporal Stability2 A – IEC 60904-9 2007, JIS C 8912, ASTM E 927-05
Spectral Match3 A – IEC 60904-9 2007, JIS C 8912, ASTM E 927-05
Operating Temp Range 20oC to 30oC

LSS solar simulator generates a continuous light spectrum corresponding to a class AAA spectrum. This system is designed to illuminate any type of solar cell up to 25 x 25 mm or more. LSS solar simulator generates a continuous light spectrum whose intensity varies from 1 W/m2 to 1000 W/m2. The simulator and I-V measurement system are controlled by the computer.
Common Measurements made in I/V Characterization of photovoltaic devices
Dark I/V measurements are commonly used to analyze the electrical characteristics of solar cells. Dark I/V measurements are more sensitive than light I/V measurements in determining parameters such as series resistance, shunt resistance, diode factor, and diode saturation currents.

Solar simulator automatically determine the photovoltaic parameters as follows
Open circuit voltage (Voc)
Short Circuit current (Isc)
Fill factor (FF)
Voltage at Pmax (Vmax)
Current at Pmax (Imax)
Maximum power output (Pmax)
Shunt resistance (Rsh) •
Series resistance (Rs) •
Characteristic resistance of solar cell (Rch) •
Photoreponse (RR)
Solar cell efficiency (n)
Solar simulator automatically determine the photovoltaic mechanism like monomolecular recombination mechanism, supra linear mechanism and etc.

LSS SOLAR SIMULATOR SYSTEM measures the followings

Solar Simulator system is controlled automatically by computer
Solar Simulator system adjusts automatically the intensity of light 0.1 W/m2 -1000 W /m2 by any step, for example from 1 W/m2 to 1000 W/m2 with 1 W/m2.
Solar Simulator system automatically measures current-voltage (I-V) under various light intensities
Solar Simulator system automatically measures power-voltage (P-V) under various light intensities
Solar Simulator system automatically analyses photovoltaic mechanism (I-V) under various light intensities
Solar Simulator system automatically measures photo transient current-time (I-t) under various light intensities
Solar Simulator system measures automatically open circuit voltage-time (Voc-t) under various light intensities
Solar Simulator system measures automatically short current-time (Isc-t) under various light intensities

SYSTEM IS UPGRADED ACCORDING TO REQUIRMENTS OF CUSTOMER
After-sales of the system, the following trainings will be given
Dye sensitized solar cell preparation and characterization Quantum dots solar cell preparation and characterization Organic solar cell preparation and characterization Silicon solar cell preparation and characterization Schott preparation and characterization of the diodes PN junction diode preparation and characterization Preparation and characterization of MIS diode To teach the calculation of all electronic parameters

TECHNICAL SPECIFICATIONS OF LSS AUTOMATIC SOLAR IV CHARACTERIZATION SYSTEM

1. Solar Simulator system automatically is controlled by computer.
2. Solar Simulator system automatically measure I-V characteristics from 1 W/cm2 -1000 W /cm2 by adjusting light intensity with step of 1 mW/cm2.
3. The intensity of solar simulator should automatically adjust by system
4. Solar simulator system should simultaneously measure I-V characteristics curve of the device, Solar Cell I-V characteristic curve, Power-voltage curve, lsc-Solar light intensity curve and photovoltaic mechanism curve and should analyze photovoltaic mechanism and write type of the mechanism on computer screen.
5. Solar Simulator should automatically measure open circuit voltage Voc and short circuit current, ISC , Shunt resistance (Rsh) • Conversion efficiency (n), Maximum power output (Pmax), Voltage at Pmax (Vmax), characteristic resistance, Rch , Fill factor (FF) • Series resistance (Rs)
6. Solar Simulator system measures automatically current-voltage (I-V) of solar cell under various solar lights
7. Solar Simulator system measures automatically short circuit current, Isc-time (Isc-t) characteristics of the solar cell.
8. System should automatically measure transient photocurrent measurements under solar light from 1 W/cm2 to 1000 W2 with step of 1 W/cm2.
9. Solar Simulator system should automatically analyze photovoltaic mechanism of solar cells a, photodiode and photodetectors with photodetector parameters.
10. System should have a source meter having the specifications
Voltage range: -24 V to +24 V
Current range: 100 nA to 500 mA
11. System should have an automatic shuttering system which automatically changes solar light from 1 W/m2 to 1000 W/m2.
12. System should have sample holder and it is comprised of two probes. Holder size should have 132.5mmx132.5mm.
13. System should have software to control measurements and analysis of data.
14. Installing and training

SOFTWARE OF THE SYSTEM

System has two software, first characterize all photovoltaic parameters

Software measure all photovoltaic parameters of solar cells by computer. The system determine all photovoltaic parameters. Software of Solar Simulator system determine the following photovoltaic parameters such as short circuit current Isc, open circuit voltage Voc, maximum power Pmax, maximum current Imax, maximum voltage Vmax, efficiency n, shunt resistance Rsh and series resistance Rs.
Also ,system analyze the automatically the photovoltaic mechanism analysis.

Second software characterize the transient photovoltaic parameters

The second software analyze the life of the solar cell and transient photocurrent measurements.
For transient photocurrent measurements, the system measure
Automatically reads open circuit voltage Voc –time
Automatically reads short circuit current Isc –time